        36V400Hz Frequency converter for Aviation
        The 36V/400Hz frequency converter power supply is designed and manufactured for Aviation and military electronic and electrical equipments.
        Introduction
        The 36V/400Hz frequency converter power supply is designed and manufactured for Aviation and military electronic and electrical equipment, which adopts high frequency switching technology. Can Be used in aircraft and airborne equipment, radar, navigation and other military electronic equipments, as well as other equipments which need 36V/400Hz power supply. The voltage and frequency of the converter can be adjustable at the range of 20%,suitable for three-phase unbalanced load, designated phase can also be used as a single-phase power supply.
        Features
        Meet the military standard of GJB572-88 and MIL-STD-704 technical requirements of aviation power specifications. 
        Intelligent control, using multi-CPU control, easy to monitor and experiment. 
        The operation is simple and convenient, and the operation parameters, operation records and fault information of the power supply can be checked through the display interface. 
        Adopted Siemens IGBT and Mitsubishi IGBT to drive, stable and excellent quality. 
        High stability, low drift, to meet the needs of high speed and very low distortion and ripple at the same time. 
        Adopt pulse width modulation (SPWM) technology to make smaller volume, light weight, low noise. 
        Excellent load protection function: with output over-voltage, under-voltage, phase fault, short-circuit output protection,ect.
        Can be designed according to customer requirements, to ensure the safety of aircraft, equipment and operators. 
        Excellent self-protection function: Adopt intelligent IGBT IPM output, with automatic over-current, over-voltage protection and independent temperature detection protection circuit. In particular, phase-missing protection of three-phase power input.
        Excellent overload protection: continuous operation at 120% overload, shutdown at 150% for 600 seconds, shutdown at 200% for 15 seconds. With isolation transformer: fully isolated output, long lifespane.
        Fast output response: for 100% loading or unloading, the output voltage stabilizing rate is stable at 0.5% (linear load) within 2ms of the response time. 
        With good conduct and anti-radiation interference function.
        Specification

        Model

        FC36400-01

        FC36400-02

        FC36400-03

        FC36400-05

        FC36400-06

        Capacity(KVA)

        1KVA

        2KVA

        3KVA

        5KVA

        6KVA

        AC Input voltage

        220V±22V /380V ±40V

        Phase

        Single phase or three phases+3wires

        Input Frequency

        50 / 60Hz ±5Hz

        AC Output voltage

        36/21VAC (28VAC-43VAC)

        Output Frequency

        400Hz ±0.4Hz (320Hz-480Hz adjustable)

        Transient
        characteristic

        The maximum overshoot is 10% and the transient recovery time is 20ms

        THD

        2%

        Crest Coefficient

        1.41±0.10

        Single harmonic content

        1.5

        Voltage modulation amplitude

        2.5V

        Display

        Frequency

        0.1Hz, maximum difference:±0.1

         

        Voltage

        0.1V,maximum difference:±1V

         

        Current

        0.1A,maximum difference:±2.5

         

        Capacity

        0.01KW,maximum difference:±5

        Efficiency

        85

        Three-phase voltage unbalance

        Maximum difference1.5V

        Phase shift

        120°±2°

        Preset function

        Standby state can be preset output voltage, output  frequency,
        output voltage up and down floating percentage

        Storage function

        Output parameters will be automatic memory, when re-turn on the power,
        the original preset value is still maintained

        Alarm function

        The alarm signal is sent out after the protective device is operated

        Protection

        Input phase missing, output short circuit, output overvoltage,
        output overload, internal overheating

        Overload

        125% for 600 seconds,150% for 60seconds,200% for 15seconds,

        Noise

        70dB

        Display

        LED display

        Shell protection level

        IP21; 0℃~+40

        Optional

        Air Plug 2. Aerial Cable (10m, 15m, 20m)

        About Us
        Company Introduction
        Principles
        Mission
        Global Certification
        Contact us
        Solution
        New Energy
        Network Solutions
        Industrial Solutions
        Household Solutions
        Motive Power Solutions
        Products
        UPS
        Telecom Power and Charger
        Batteries
        Photovoltaic Energy
        Inverter and Stabilizer
        Support
        Partners
        Technical Support
         
         
         

        性视频免在线观看视频